Texas, USA · U.S. & International Industrial Supply
Products & Sourcing › Fire Sprinkler & Protection

Fire Sprinkler & Fire Protection Parts — USA Sourcing

UL Listed and FM Approved sprinklers, alarm and dry pipe valves, backflow preventers, flow switches and sprinkler system parts from leading U.S. manufacturers, for fire protection contractors and facilities in the GCC, Southeast Asia and worldwide.

Send RFQ for Fire Protection Parts
What we source

Sprinkler system components and spares

Send the manufacturer, model, K-factor and temperature rating, or the part number from your system drawings, and we will quote matching listed products. Spares for new projects, expansions and routine replacement.

  • Sprinkler heads: pendent, upright, sidewall, dry and concealed
  • Alarm check valves, dry pipe valves and riser check valves
  • Backflow preventers: double check and reduced pressure assemblies
  • Waterflow switches, pressure switches and supervisory devices
  • Riser manifolds, test and drain valves, gauges
  • Grooved and CPVC fittings, couplings and cement
  • Hangers, sway bracing and beam clamps
  • Air compressors and dryers for dry and pre-action systems
  • Escutcheons, cover plates, cabinets and sprinkler wrenches
Manufacturers and models

Fire protection parts buyers commonly request

Examples of the manufacturers and models we source. Send any model number from these or other listed fire protection manufacturers.

Product typeManufacturers and modelsNotes
Standard and quick-response sprinklersViking VK1001 K5.6 standard-response upright, VK104 K5.6 horizontal sidewall, VK630 K8.0 quick-response extended-coverage sidewall, VK427 K5.6 institutional, VK530 K11.2 extra large orifice (ELO) upright; Reliable and Tyco pendent and upright modelsSpecify K-factor, temperature rating, finish and thread
Dry pendent sprinklersViking VK150; Reliable F3QR56 K5.6 quick response; Tyco TY3935For cold stores and unheated areas; specify exact length
Alarm and riser check valvesViking Model J-1 alarm check valve, F-1 Easy Riser swing check; Reliable Model E wet alarm valveWith trim, retard chambers and gauges on request
Dry pipe valves and accessoriesViking VXR dry valve, Model D automatic drip checkComplete trim packages available
Deluge and pre-action valvesViking pilot-operated and PTR electric-release deluge valves and trimTransformer, loading-bay and foam systems
Floor control and test-and-drainViking EASYPAC floor control riser groove assemblies with test and drain (2 in to 6 in); AGF Manufacturing TESTANDRAIN and riser componentsFloor-by-floor control in high-rise buildings
Backflow preventersAmes C200 double check, Ames Colt C400 reduced pressure zone; Zurn Wilkins 375AST, 350A; WattsSizes from 3/4 in to 10 in
Flow and pressure switchesPotter VSR waterflow switch with retard, Potter pressure switches; Viking alarm test valve unitsFor fire alarm and supervisory signals
Check valvesNIBCO F908W flanged swing check; bronze swing and in-line checksGrooved, flanged and threaded ends
CPVC pipe fittingsViking Plastics CPVC fire sprinkler pipe, 90-degree elbows, tees and V5001 socket couplings; FS5 one-step cement; Lubrizol BlazeMaster CPVCFor light-hazard wet systems
Hangers and seismic bracingTolco Fig 980 universal swivel sway brace attachment, Fig 29 double-offset CPVC hanger; nVent CADDY universal wide-mouth beam clamps; ASC Engineered Solutions AF777 swivel attachment connectorsListed hangers and bracing for sprinkler pipe
Air compressors and dryersGeneral Air Products Dry Air Pac and tank-mounted compressors, AMD-1 air maintenance device; Viking maintenance air compressorsFor dry and pre-action systems; confirm 50 Hz supply
Sprinkler guards, caps and escutcheonsEG-100 ESFR sprinkler guards; Viking 10364 recessed sprinkler cap protectors; recessed and raised surface-mount escutcheonsWarehouses, car parks and finished ceilings
Fire extinguishers and fittingsKidde extinguishers; Brecco, Noble Company, Smith-Cooper and United Brass Works fittings and fire hose valvesBuilding fit-outs and replacements
Fire pump controllers and enginesFiretrol, Metron and Joslyn Clark electric and diesel fire pump controllers, transfer switches and jockey pump controllers; Clarke diesel fire pump engines and spare partsNFPA 20 fire pump rooms; specify voltage, frequency and horsepower
Backflow test equipmentMid-West Instrument 845-5 backflow prevention test kitsAnnual testing of backflow assemblies
Antifreeze and tanksListed sprinkler antifreeze solutions; expansion tanksFor antifreeze loops in cold-store areas

Vision Target Inc. is an independent sourcing company and is not an authorized distributor of the manufacturers listed. Trademarks are the property of their owners and are used only to identify the products we source.

Who uses them

Where these parts are used

Fire Protection Contractors

Listed sprinklers, valves and trim for new installations and system expansions.

Facility Management

Replacement sprinklers and valve parts for routine inspection and maintenance findings.

Warehouses & Logistics

Sprinklers, dry systems and compressors for storage buildings and cold stores.

Oil & Gas and Petrochemical

Valves, backflow assemblies and spares for plant fire water systems.

Hotels, Malls & Hospitals

Concealed and quick-response sprinklers and riser components for commercial buildings.

Marine & Ports

Sprinkler and fire water system parts for terminals, warehouses and vessels.

Before you order

What to include in your RFQ

Part details

  • Manufacturer and model, or the sprinkler identification number (SIN) stamped on the deflector
  • K-factor, temperature rating, response type, finish and thread size
  • Valve size, end connections and required trim

Points we check

  • UL Listing and FM Approval required by your project specification
  • Sprinkler temperature rating suited to hot Gulf roof spaces
  • 50 Hz supply for compressors and dryers; local civil-defence approval is arranged by your contractor

Send RFQ for Fire Protection Parts Safety & PPE

From recent RFQs and quotations

Fire protection part numbers we have quoted

Examples of manufacturer part numbers from recent buyer RFQs and our quotations. A listing here does not mean we hold stock: availability, lead time and price are confirmed for each RFQ.

ManufacturerPart numberDescription
AmerexB45610 lb ABC dry chemical extinguisher
AmerexA41120 lb ABC dry chemical extinguisher
AmerexB500T5 lb ABC dry chemical extinguisher
Darley2801207Fire pump inboard head (replaces 2801203)
Darley3600557Pump oil seal

What to include in your RFQ

  • Manufacturer and full part number (a nameplate photo helps)
  • Quantity and unit of measure
  • Destination country and preferred terms: EXW Houston, Texas or CIF
  • Documents you need: Certificate of Origin, Certificate of Compliance, datasheets or calibration certificates

Send RFQ

Need fire sprinklers or valves from the USA?

Send the manufacturer, model and quantity. We will reply with availability, lead time and a quotation.